        出口定制-电源分配板 电源分线器(可监控型 输出状态,带报警信号)

        输入电压:12-24V AC或DC都可以工作 输出:10路监控输出(继电器报警信号输出) 任何1路故障都会触发报价信号

        • 总输出功率: 0-150W
        • 总输出电流: 8.5A
        • 输出电压: DC12V
        • 输出路数: 10路
        关闭
        在线询价
        建议用右边在线方式沟通,更准确及时。

        Features

         ?    User friendly solution to low voltage power distribution

         ?    State-of-the-art SMD technology

         ?    10 Individual fused and monitored outputs

         ?    Operating voltage 12-24V AC or DC

        特征

        ?用户友好的低压配电解决方案

        ?先进的SMD技术

        ?10个单独融合和监控的输出

        ?工作电压12-24V ACDC12-24

        Specifications

          Model: Mon 02

          Input Voltage:  12-24V AC or DC

         Output:      10 x fused and monitored outputs

        Total Current:  10A Max

          Relay Rating: 3A@0-250V AC or 30V DC

        Size:   110 x 93mm

         产品规格

         型号:Mon 02
        输入电压:12-24V ACDC

        输出:10个融合和监控输出(继电器报警信号输出)

        总电流:10A最大

        继电器额定值:3A @ 0-250V AC或 30V DC

        尺寸:110 x 93mm

        Operation Voltage Jumper Setting

         Mon 02 May be used for use 12-24V AC or DC devices and ships from the factory set for 24V AC for operation.

         If 12VDC operation is desired, simply change the Jumper to 12V DC.

         工作电压跳线设置

         Mon 02可用于使用12-24V交流或直流设备,出厂默认设置的24V AC运行。

         如果需要12VDC操作,只需将跳线更改为12V DC。

         Common Fault Relay

         Mon 02 includes a common fault output relay (rated at 1A) to drive external devices, such as alarm panels, sounders and DVR alarm inputs, ensuring that failure of any individual circuit does not go unnoticed.

         During normal operation all green circuit status LEDs 9 will be lit. In the event of a fuse failure, the corresponding circuit status LED will extinguish, the Common Fault Relay 7 will change state and the Common LED 8 will light.

          When the fault is rectified and the fuse replaced, LEDs & Relay will return to normal.

        故障输出继电器

         Mon 02包括一个常见故障输出继电器(额定值为3A),以驱动外部设备,如报警面板,发声器和DVR报警输入,确保任何单独电路的故障不会被忽视。

         在正常操作期间,所有绿色电路状态LED 9将亮起。 在保险丝故障的情况下,相应的电路状态指示灯将熄灭,公共故障继电器7将改变状态,通用LED 8将点亮。